Callender Lake Dam

Callender Lake Dam is an earth dam located in Van Zandt County, Texas, built in 1958. It carries a High hazard potential classification.

About Callender Lake Dam

The primary purpose of Callender Lake Dam is recreation. The dam creates a reservoir used for recreational activities such as fishing, boating, and swimming. The dam is owned by Callender Lake Poia (private). It impounds the Slater Creek near Brownsboro.

The dam stands 35 feet tall and stretches 1,600 feet across, creates a reservoir covering 328 acres, has a maximum storage capacity of 5,316 acre-feet, and collects water from a drainage area of 9 square miles. Completed in 1958, the structure is well into its service life at over 50 years old.

This dam carries a high hazard potential classification, which means that a failure or uncontrolled release of water would likely cause loss of human life. This classification reflects the consequences of failure, not the likelihood — it indicates that people live or work in the area downstream. An emergency action plan is in place for this dam. The most recent inspection on record was 10/05/2017. That was 8 years ago, which is on the longer end for a high-hazard structure.

At 35 feet, this dam is taller than 82% of dams nationwide.

Living Downstream

If you live or work downstream of this dam, consider taking these steps: learn your local evacuation routes, check whether your county emergency management office has a dam failure inundation map, and sign up for local emergency alerts. The Texas dam safety program can provide more specific information about emergency planning for this structure.

Search for dams near your address to see all dams in your area with hazard classifications and safety data.

High HazardNot Rated ConditionEmergency Action Plan: Yes

Location

StateTexas
CountyVan Zandt
Nearest CityBrownsboro
River/StreamSlater Creek
Coordinates32.35610, -95.69587

Physical Characteristics

Dam TypeEarth
NID Height35 ft
Dam Height31 ft
Dam Length1,600 ft
Year Completed1958 (68 years old)

Storage & Hydraulics

NID Storage5,316 acre-ft
Max Storage5,316 acre-ft
Normal Storage3,414 acre-ft
Surface Area328 acres
Drainage Area9 sq mi
Max Discharge2,510 cfs
Spillway TypeUncontrolled

Ownership & Safety

PurposeRecreation
OwnerCALLENDER LAKE POIA
Owner TypePrivate
Hazard ClassificationHigh
Condition AssessmentNot Rated
Last Inspection10/05/2017
Emergency Action PlanYes

Identifiers

NID IDTX02800
Federal IDTX02800
More InfoState Dam Safety Program