Sp 2 Dam is an earth dam located in Choctaw County, Mississippi, built in 1999. It carries a Low hazard potential classification.

Hazard potentialLowFailure would cause limited damage
ConditionNot assessed
Emergency action planNot reported
Last inspectionNot reported
Height19 ft
Built199927 years ago

Dam profile

NID height · 19 ft
19 FT TWO-STORY HOUSEMEDIAN U.S. DAM · 24 FT

19 ft tall and 1,065 ft long. Height is drawn to scale against a two-story house, about 25 ft; the profile is a generic embankment section and the water level is illustrative.

About Sp 2 Dam

The primary purpose of Sp 2 Dam is tailings. Tailings dams contain waste material from mining operations — typically a slurry of finely ground rock left over after valuable minerals have been extracted. These structures require ongoing monitoring because tailings can contain heavy metals and other contaminants. The dam is owned by Mississippi Lignite Mining Co. (private). It impounds the Unt of Middle Bywy Creek.

The dam stands 19 feet tall and stretches 1,065 feet across, creates a reservoir covering 9 acres, has a maximum storage capacity of 248 acre-feet, and collects water from a drainage area of 0 square miles. Completed in 1999, the structure is 27 years old.

This dam has a low hazard potential classification, meaning that failure would cause minimal damage, limited primarily to the dam owner's property, with no expected loss of life.

Search for dams near your address to see all dams in your area with hazard classifications and safety data.

Location

StateMississippi
CountyChoctaw
River/StreamUnt of Middle Bywy Creek
Coordinates33.39012, -89.23132

Physical Characteristics

Dam TypeEarth
NID Height19 ft
Dam Height19 ft
Dam Length1,065 ft
Year Completed1999 (27 years old)

Storage & Hydraulics

NID Storage248 acre-ft
Max Storage248 acre-ft
Normal Storage36 acre-ft
Surface Area9 acres
Drainage Area0 sq mi
Max Discharge394 cfs
Spillway TypeUncontrolled

Ownership & Safety

PurposeTailings
OwnerMississippi Lignite Mining Co.
Owner TypePrivate
Hazard ClassificationLow
Condition AssessmentNot assessed
Emergency Action PlanNot Required

Identifiers

NID IDMS03542
Federal IDMS03542
More InfoState Dam Safety Program